Alarm failure
Over-range alarm indicates that the machine has reached its limit during operation. Please follow the following steps to check:
1. Whether the designed figure size is beyond the processing range.
2. Check whether the connecting line between the machine motor shaft and the screw is loose. If so, tighten the screw.
3. Whether the machine and computer are grounded correctly.
4. Does the current coordinate value exceed the soft limit value range?